List / Step Sweep

This topic describes the parameters of the List / Step Sweep tab of the RF Output block.

The signal generator supports the following two types of sweeping through a set of frequency and amplitude points:

The List / Step Sweep feature is available only on those channels for which you select Independent as the Group Configuration. For all other Group Configurations, the List / Step Sweep tab is not displayed in the RF Output block.

Enable Sweep

Frequency Sweep State

Power Sweep State

Waveform Sweep State

Sweep Type

Sweep Direction

Sweep Repeat

Single Sweep

Sweep Retrace

Sweep Out Points

Sweep Out Single Point

Operation Mode

Manual Point

Abort Sweep (per channel)

Abort Sweep (all channels)

Initiate Immediate per Channel

Initiate Immediate All Channels

Trigger Sweep

Trigger Sweep Immediate

Edit Step Sweep (Step Sweep Configuration) ClosedSetup

Frequency Start

Frequency Stop

Frequency Center

Frequency Span

Power Start

Power Stop

Number of Points

Current Sweep Point

Step Dwell Time

Step Spacing

Linear Frequency Step

Logarithmic Frequency Step

Edit List Sweep (List Sweep Configuration) ClosedSetup

Frequency

Power

Dwell Time

Dwell Type

Dwell Type List State

Current Sweep Point

Waveforms

Frequency Points

Power Points

Waveform Points

Dwell Time Points

Import List Sweep Table

Export List Sweep Table

Preset List with Defaults

Preset List with Step Sweep

Edit Triggers ClosedSetup

Sweep Trigger

Trigger Type

Trigger Source

External Trigger Source

External Trigger Polarity

Point Trigger

Point Trigger Source

External Trigger Source

External Trigger Polarity

 

Enable Sweep

Enables the Sweep signaling.

GUI Location

RF Output > List / Step Sweep > Enable Sweep

SCPI Command

[:SOURce][:RF<channel>]:LIST[:STATe] ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST[:STATe]?

SCPI Example

:LIST ON

:LIST?

Dependencies

Unavailable when Group Configuration is not Independent.

To enable sweep, at least one of Frequency, Power, or Waveform Sweep State must be ON. When none of these are ON, Enable Sweep is set to OFF and is unchangeable.

Couplings
  • When Frequency Mode is set to List or Sweep, List/Step Sweep State is turned on.

  • When Power Mode is set to List or Sweep, List/Step Sweep State is turned on.

  • When LARB State is set to ON, List/Step Sweep State is turned on.

  • When all states of Frequency Sweep State, Power Sweep State, and Waveform Sweep State are turned off, List/Step Sweep State is turned off.

Preset

OFF

State Saved

Yes

Frequency Sweep State

Sets the state of frequency sweep.

GUI Location

RF Output > List / Step Sweep > Frequency

SCPI Command

[:SOURce][:RF<channel>]:LIST:FREQuency:STATe ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:FREQuency:STATe?

SCPI Example

:LIST:FREQ:STAT ON

:LIST:FREQ:STAT?

Couplings

  • When RF Frequency is changed, the Frequency Sweep State is set to OFF .

  • When Frequency Mode is set to Fixed or CW, Frequency Sweep State is set to OFF.

  • When Frequency Mode is set to List or Sweep, Frequency Sweep State is set to ON.

State Saved

Yes

Preset

ON

Power Sweep State

Sets the state of Power sweep.

GUI Location

RF Output > List / Step Sweep > Power

SCPI Command

[:SOURce][:RF<channel>]:LIST:POWer:STATe ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:POWer:STATe?

SCPI Example

:LIST:POW:STAT ON

:LIST:POW:STAT?

Dependencies

  • When RF Power is changed, the Power Sweep State is set to OFF.

  • When User Power Limit Enable is set to On, the Power Sweep State is set to OFF.

Note that the Power Sweep State is not turned off when User Power Limit Enable is set to OFF.

  • When Power Mode is set to Fixed, Power Sweep State is set to OFF.

  • When Power Mode is set to List or Sweep, Power Sweep State is set to ON.

State Saved

Yes

Preset

ON

Waveform Sweep State

Sets the state of Waveform sweep.

GUI Location

RF Output > List / Step Sweep > Waveform

SCPI Command

[:SOURce][:RF<channel>]:LIST:WAVeform:STATe ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:WAVeform:STATe?

SCPI Example

:LIST:WAV:STAT ON

:LIST:WAV:STAT?

Notes

For N5185A: This setting is always set to OFF.

Dependencies

The Waveform Sweep State can be set to On only when the Sweep Type is set to List.

State Saved

Yes

Preset

OFF

Couplings

  • When Sweep Type is Step, Waveform Sweep State is set to OFF.

  • When LARB State is set to ON, Waveform Sweep State is set to ON.

  • When LARB State is set to OFF, Waveform Sweep State is set to OFF.

  • When turning on Waveform Sweep State, all of the channel’s Enable Vector Modulation Signals are set to OFF.

  • When any of the channel’s Enable Vector Modulation Signals are set to ON, Waveform Sweep State is set to OFF.

Sweep Type

Sets the type of Sweep by toggling between the following two types of sweeps.

GUI Location

RF Output > List / Step Sweep > Sweep Type

SCPI Command

[:SOURce][:RF<channel>]:LIST:TYPE STEP|LIST

[:SOURce][:RF<channel>]:LIST:TYPE?

SCPI Example

:LIST:TYPE LIST

:LIST:TYPE?

Preset

STEP

Range

Step|List

State Saved

Yes

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:TYPE

Sweep Direction

Sets the direction of a List or Step sweep.

GUI Location

RF Output > List / Step Sweep > Sweep Direction

SCPI Command

[:SOURce][:RF<channel>]:LIST:DIRection UP|DOWN

[:SOURce][:RF<channel>]:LIST:DIRection?

SCPI Example

:LIST:DIR UP

:LIST:DIR?

Preset

UP

Range

Up|Down

State Saved

Yes

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:DIRection

Sweep Repeat

Sets either a continuous or single List or Step sweep per channel. Execution of this command does not affect a sweep in progress.

GUI Location

RF Output > List / Step Sweep > Sweep Repeat

SCPI Command

[:SOURce][:RF<channel>]:LIST:REPeat:CONTinuous ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:REPeat:CONTinuous?

SCPI Example

:LIST:REP:CONT OFF

:LIST:REP:CONT?

Preset

ON

Range

Single | Continuous

  • Continuous    ON (1) - This choice sets continuous sweep where, after the completion of the previous sweep, the current sweep restarts automatically or waits until the appropriate trigger source is received.

  • Single    OFF (0) - This choice sets a single sweep.

State Saved

Yes

Backward Compatibility SCPI

N51xxB:

:INITiate:CONTinuous[:ALL]

Backward Compatibility Notes

For N51xxB:

Alias :INITiate:CONTinuous[:ALL] to :SOURce:RF1:LIST:REPeat:CONTinuous

The original N51xxB SCPI command is categorized for all channel command since it starts from ":INITiate".

The SCPI command mnemonic for N5186A/N5185A is defined to support channel 1 for the backward compatibility.

Single Sweep

GUI option only.

Clicking this option performs the following two tasks:

This option is not active if Sweep Enable is set to Off.

GUI Location

RF Output > List / Step Sweep > Single Sweep

SCPI Command

No direct SCPI command is available.

SCPI Example

N/A

Notes

GUI only

Momentary action

No direct SCPI command is available. Run the following equivalent commands:

:INITiate:CONTinuous[:ALL] OFF (when Sweep Repeat is Cont)

[:SOURce][:RF<channel>]:SWEep:INITiate[:IMMediate][:ALL]

[:SOURce][:RF<channel>]:TSWep

Dependencies

When Operation Mode is set to Manual, the Single Sweep button is disabled.

State Saved

No

Sweep Retrace

Configures the sweep to retrace to the first sweep point, or stop at the last sweep point upon completion of each sweep.

GUI Location

RF Output > List / Step Sweep > Sweep Retrace

SCPI Command

[:SOURce][:RF<channel>]:LIST:RETRace ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:RETRace?

SCPI Example

:LIST:RETR OFF

:LIST:RETR?

Preset

ON

State Saved

Yes

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:RETRace

Sweep Out Points

Sets the behavior of the Sweep Out output signal as one of the following two options/

and a single pulse for the dwell of just one selected point of the List/Sweep.

GUI Location

RF Output > List / Step Sweep > Sweep Out Points

SCPI Command

[:SOURce][:RF<channel>]:LIST:SOUT ALL|SPOint

[:SOURce][:RF<channel>]:LIST:SOUT?

SCPI Example

:LIST:SOUT ALL

:LIST:SOUT?

Preset

ALL

Range

All (ALL)

Single (SPOint)

State Saved

Yes

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:SOUT

Sweep Out Single Point

Enabled when Sweep Out Points is set to Single Point.

When the Sweep Out is configured to output a single pulse for the dwell of just one selected point of the List/Sweep, this setting sets that specific point of the sweep. The value is limited to the current number of points in the active columns of the list when the Sweep Out selection is Single Point.

GUI Location

RF Output > List / Step Sweep > Sweep Out Points set to Single Point > Single Point

SCPI Command

[:SOURce][:RF<channel>]:LIST:SOUT:SPOint <value>

[:SOURce][:RF<channel>]:LIST:SOUT:SPOint?

SCPI Example

:LIST:SOUT:SPO 100

:LIST:SOUT:SPO?

Dependencies
  • When Sweep Type is Step, the value is clipped by the step points of the step sweep.

  • When Sweep Type is List, the value is clipped by the step points of the list sweep.

  • This value is used when Sweep Out Point is set to Single Point.

Preset

1

State Saved

Yes

Min

1

Max

65535

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:SOUT:SPOint

Operation Mode

Sets the operating mode for the current List / Step sweep.

If you set the Operation Mode to MANual, during a sweep, the sweep stops at the current point.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep or Edit List Sweep > Operation Mode

SCPI Command

[:SOURce][:RF<channel>]:LIST:MODE AUTO|MANual

[:SOURce][:RF<channel>]:LIST:MODE?

SCPI Example

:LIST:MODE MAN

:LIST:MODE?

Preset

AUTO

State Saved

Yes

Range

AUTO|Manual

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:MODE

Manual Point

Sets the sweep point, controlling the frequency and power output when Sweep Operation Mode is Manual.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep or Edit List Sweep > Manual Point

SCPI Command

[:SOURce][:RF<channel>]:LIST:MANual <integer>|UP|DOWN

[:SOURce][:RF<channel>]:LIST:MANual?

SCPI Example

:LIST:MAN 2

:LIST:MAN?

Notes If the point selected is beyond the length of the longest enabled list, then the point will be clipped and an error is generated.

Preset

1

State Saved

Yes

Min

1

Max

65535 (Step Sweep)

3201 (List Sweep)

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:MANual

Abort Sweep (per channel)

Remote command only.

Aborts the sweep in progress for the specified channel.

SCPI Command

[:SOURce][:RF<channel>]:LIST:ABORt

SCPI Example

:LIST:ABOR

Notes

Momentary action

Preset

N/A

State Saved

No

Abort Sweep (all channels)

Remote command only.

Aborts the list or step sweep in progress for all channels.

If INIT:CONT[:ALL] is set to On, the sweep will re-initiate immediately.

SCPI Command

:ABORt

SCPI Example

:ABOR

Notes

Momentary action

Preset

N/A

State Saved

No

Backward Compatibility SCPI

N5182B:

:ABORt

Initiate Immediate per Channel

Remote command only.

Initiates the sweep on the specified channel.

SCPI Command

[:SOURce][:RF<channel>]:LIST:INITiate[:IMMediate][:ALL]

SCPI Example

:LIST:INIT

Notes

Command is ignored if a sweep is already in progress.

Couplings

When Sweep Trigger Source is Immediate, a single sweep is armed and started.

When Sweep Trigger Source is not Immediate , a single sweep is armed, but not started.

State Saved

No

Initiate Immediate All Channels

Remote command only.

Initiates the sweep on all channels.

SCPI Command

:INITiate[:IMMediate][:ALL]

SCPI Example

:INIT

Notes

Command is ignored if a sweep is already in progress.

Couplings

When Sweep Trigger Source is Immediate, a single sweep is armed and started.

When Sweep Trigger Source is not Immediate , a single sweep is armed, but not started.

State Saved

No

Backward Compatibility SCPI

N5182B:

:INITiate[:IMMediate][:ALL]

Trigger Sweep

Remote command only.

Aborts the current sweep.

SCPI Command

[:SOURce][:RF<channel>]:TSWeep

SCPI Example

:TSW

Notes

Momentary action

Couplings

When Sweep Trigger Source is Immediate, arms and starts a single sweep.

When Sweep Trigger Source is not Immediate, arms a single sweep.

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:TSWeep

Trigger Sweep Immediate

Remote command only.

Triggers an armed List Sweep or Step Sweep to immediately start without the occurrence of the selected trigger.

SCPI Command

[:SOURce][:RF<channel>]:LIST:TRIGger:IMMediate

SCPI Example

:LIST:TRIG:IMM

Notes

Momentary action

State Saved

No

Backward Compatibility SCPI

N51xxB

:TRIGger[:SEQuence][:IMMediate]

Backward Compatibility Notes

For N51xxB:

Alias :TRIGger[:SEQuence][:IMMediate] to :SOURce:RF1:LIST:TRIGger:IMMediate

Edit Step Sweep (Step Sweep Configuration)

The Edit Step Sweep button opens the Step Sweep screen that allows you to configure the steps for Step Sweep. You can configure a minimum of 2 steps and maximum 65535 steps for Step sweep.

Frequency Start

Sets the first frequency point in a Step sweep.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Frequency Start

SCPI Command

[:SOURce][:RF<channel>]:SWEep:FREQuency:STARt <freq>

[:SOURce][:RF<channel>]:SWEep:FREQuency:STARt?

SCPI Example

:SWE:FREQ:STAR 1e9

:SWE:FREQ:STAR?

Preset

Maximum RF Frequency (CW). See Frequency CW

State Saved

Yes

Min Minimum RF Frequency (CW). See Frequency CW
Max Maximum RF Frequency (CW). See Frequency CW

Resolution

0.00001 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:FREQuency:STARt

Backwards Compatibility Notes

For N51xxB:

Alias [:SOURce][:RF<channel>]:FREQuency:STARt to [:SOURce][:RF<channel>]:SWEep:FREQuency:STARt

Frequency Stop

Sets the last frequency point in the Step sweep.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Frequency Stop

SCPI Command

[:SOURce][:RF<channel>]:SWEep:FREQuency:STOP <freq>

[:SOURce][:RF<channel>]:SWEep:FREQuency:STOP?

SCPI Example

:SWE:FREQ:STOP 3e9

:SWE:FREQ:STOP?

Preset

Maximum RF Frequency (CW). See Frequency CW

State Saved

Yes

Min Minimum RF Frequency (CW). See Frequency CW
Max Maximum RF Frequency (CW). See Frequency CW

Resolution

0.00001 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:FREQuency:STOPt

Backward Compatibility Notes

For N51xxB:

Alias [:SOURce][:RF<channel>]:FREQuency:STOPt to [:SOURce][:RF<channel>]:SWEep:FREQuency:STOP

Frequency Center

Remote command only

Sets the center frequency for a Step Sweep. The center frequency symmetrically divides the selected frequency span and is coupled to the start and stop frequency settings. The frequency range and reset values are dependent on the signal generator model and option number.

SCPI Command

[:SOURce][:RF<channel>]:SWEep:FREQuency:CENTer <freq>

[:SOURce][:RF<channel>]:SWEep:FREQuency:CENTer?

SCPI Example

:SWE:FREQ:CENT 3 GHZ

:SWE:FREQ:CENT?

Couplings Frequency Start and Frequency Stop are calculated with Frequency Center and Frequency Span. Changing Frequency Center alters Frequency Start and Frequency Stop.

Preset

Maximum RF Frequency (CW). See Frequency CW

State Saved

Yes

Min Minimum RF Frequency (CW). See Frequency CW
Max Maximum RF Frequency (CW). See Frequency CW

Resolution

1 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:FREQuency:CENTer

Backwards Compatibility Notes

For N51xxB:

Alias [:SOURce][:RF<channel>]:FREQuency:CENTer to [:SOURce][:RF<channel>]:SWEep:FREQuency:CENTer

Frequency Span

Remote command only

Sets the length of the step sweep frequency range for the specified channel. Span setting is symmetrically divided by the selected center frequency and is coupled to the start and stop frequency settings.

SCPI Command

[:SOURce][:RF<channel>]:SWEep:FREQuency:SPAN <freq>

[:SOURce][:RF<channel>]:SWEep:FREQuency:SPAN?

SCPI Example

:SWE:FREQ:SPAN 3 GHZ

:SWE:FREQ:SPAN?

Notes Span value returns a negative value when Frequency Start is bigger than Frequency Stop. The query for the optional MAXimum or MINimum returns the span frequency limits for the current Frequency Center.

Dependencies

Changing Frequency Span alters Frequency Start and Frequency Stop settings.

Preset

0 Hz

State Saved

Yes

Min

- (maximum RF Frequency (CW) - minimum RF Frequency (CW))

See Frequency CW

Max

(maximum RF Frequency (CW) - minimum RF Frequency (CW))

See Frequency CW

Resolution

1 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:FREQuency:SPAN

Backward Compatibility Notes

For N51xxB:

Alias [:SOURce][:RF<channel>]:FREQuency:SPAN

to

[:SOURce][:RF<channel>]:SWEep:FREQuency:SPAN

Power Start

Sets the first amplitude point in a Step sweep.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Power Start

SCPI Command

[:SOURce][:RF<channel>]:SWEep:POWer:STARt <value><unit>

[:SOURce][:RF<channel>]:SWEep:POWer:STARt?

SCPI Example

:SWE:POW:STAR -60

:SWE:POW:STAR?

Preset

Minimum RF Power

See Power (Total RMS)

State Saved

Yes

Min

Minimum RF Power

See Power (Total RMS)

Maximum

Maximum RF Power

See Power (Total RMS)

Resolution

0.01 Bm

Backwards Compatibility SCPI

N51xxB:

[:SOURce]:POWer:STARt

Backwards Compatibility Notes

For N51xxB:

Alias [:SOURce][:RF<channel>]:POWer:STARt

to

[:SOURce][:RF<channel>]:SWEep:POWer:STARt

Power Stop

Sets the last amplitude point in a Step sweep.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Power Stop

SCPI Command

[:SOURce][:RF<channel>]:SWEep:POWer:STOP <value><unit>

[:SOURce][:RF<channel>]:SWEep:POWer:STOP?

SCPI Example

:SWE:POW:STOP -20

:SWE:POW:STOP?

Preset

Minimum RF Power

See Power (Total RMS)

State Saved

Yes

Min

Minimum RF Power

See Power (Total RMS)

Max

Maximum RF Power

See Power (Total RMS)

Resolution

0.01 Bm

Backward Compatibility SCPI

N51xxB:

[:SOURce]:POWer:STOP

Backward Compatibility Notes

For N51xxB:

Alias :[SOURce][:RF<channel>]:POWer:STOP

to

[:SOURce][:RF<channel>]:SWEep:POWer:STOP

Number of Points

Sets the number of step sweep points.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Number of Points

SCPI Command

[:SOURce][:RF<channel>]:SWEep:POINts <integer>

[:SOURce][:RF<channel>]:SWEep:POINts?

SCPI Example

:SWE:POIN 201

:SWE:POIN?

Preset

101

State Saved

Yes

Min

2

Max

65535

Resolution

1

Backward Compatibility SCPI

N51xxB:

[:SOURce]:SWEep:POINts

Current Sweep Point

Query only. Returns the current sweep point.

SCPI Command

[:SOURce][:RF<channel>]:SWEep:CPOint?

SCPI Example

:SWE:CPO?

Notes

When Sweep Type is Step, returns the current sweep point of Step Sweep.

When Sweep Type is List, returns the current sweep point of List Sweep.

State Saved

No

Backward Compatibility SCPI

N51xxB:

[:SOURce]:SWEep:CPOint

Step Dwell Time

Sets the dwell time for a Step sweep. The dwell time is the amount of time the sweep is guaranteed to pause after setting the frequency and/or power for the current point.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Step Dwell Time

SCPI Command

[:SOURce][:RF<channel>]:SWEep:DWELl <time>

[:SOURce][:RF<channel>]:SWEep:DWELl?

SCPI Example

:SWE:DWEL 0.01

:SWE:DWEL?

Preset

2.00e-3

State Saved

Yes

Min

100 us

Max

100 s

Resolution

1e-6

Backward Compatibility SCPI

N5182B:

[:SOURce]:SWEep:DWELl

Step Spacing

Sets the sweep mode. The instrument uses the specified start frequency, stop frequency, and number of points for both linear and log sweeps.

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Step Spacing

SCPI Command

[:SOURce][:RF<channel>]:SWEep:SPACing LINear|LOGarithmic

[:SOURce][:RF<channel>]:SWEep:SPACing?

SCPI Example

:SWE:SPAC LOG

:SWE:SPAC?

Preset

LIN

Range

Linear (LIN)

Logarithmic (LOG)

State Saved

Yes

Backward Compatibility SCPI

N51xxB:

[:SOURce]:SWEep:SPACing

Linear Frequency Step

Sets the step size for a linear step sweep in frequency (difference between frequency points).

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Linear Frequency Step

SCPI Command

[:SOURce][:RF<channel>]:SWEep[:FREQuency]:STEP[:LINear <value><unit>

[:SOURce][:RF<channel>]:SWEep[:FREQuency]:STEP[:LINear?

SCPI Example

:SWE:STEP 10e6

:SWE:STEP?

Notes

Linear frequency step size returns a negative value when Frequency Start is bigger than Frequency Stop.

Couplings Setting the Linear Frequency Step Size will determine the number of points in the step sweep, based on the current start and stop frequencies. Due to the integer number of step points, the step size may be adjusted to yield a true linear sweep between the start and stop frequencies.

Preset

0.0 Hz

State Saved

Yes

Min

  • 0 when <frequency stop> >= <frequency start>

  • <frequency stop> - <frequency start> when <frequency stop> < <frequency start>

Max

  • <frequency stop> - <frequency start> when <frequency stop> >= <frequency start>

  • 0 when <frequency stop> < <frequency start>

Resolution

0.00001 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:SWEep[:FREQuency]:STEP:[LINear]

Logarithmic Frequency Step

This setting is displayed when Step Spacing is set to Logarithmic.

Sets the step size for a logarithmic step sweep in frequency (ratio between frequency points), expressed as a percentage (%).

GUI Location

RF Output > List / Step Sweep > Edit Step Sweep > Logarithmic Frequency Step

SCPI Command

[:SOURce][:RF<channel>]:SWEep[:FREQuency]:STEP:LOGarithmic <value>

[:SOURce][:RF<channel>]:SWEep[:FREQuency]:STEP:LOGarithmic?

SCPI Example

:SWE:STEP:LOG 10

:SWE:STEP:LOG?

Couplings Setting the logarithmic frequency step size will determine the number of points in the step sweep, based on the current start and stop frequencies. Due to the integer number of step points, the step size may be adjusted to yield a true logarithmic sweep between the start and stop frequencies.

Notes

This setting is indicated when Step Spacing is Logarithmic.

Preset

0.0

State Saved

Yes

Min

0.0

Max

-

Resolution

0.01

Backward Compatibility SCPI

N51xxB:

[:SOURce]:SWEep[:FREQuency]:STEP:LOGarithmic

Edit List Sweep (List Sweep Configuration)

The Edit List Sweep button opens the List Sweep screen that allows you to configure the steps for List Sweep. You can configure a minimum of 2 steps and maximum 3201 steps for List sweep.

The table row sizes of Frequency, Power, Waveform and Dwell Time are always same.

Frequency

Sets the frequency values for the current List sweep points. The maximum number of List sweep points is 3,201. The variable is expressed in units of hertz (Hz). The setting enabled by this command is not affected by signal generator power–on, preset, or *RST.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Frequency

SCPI Command

[:SOURce][:RF<channel>]:LIST:FREQuency <value>,<value>

[:SOURce][:RF<channel>]:LIST:FREQuency?

SCPI Example

:LIST:FREQ 1e9,2e9

:LIST:FREQ?

Dependencies

The list size is adjusted so that the same number is used in Frequency, Power, Waveform, and Dwell Time. The list number is the maximum row size (list size) in Frequency, Power, Waveform and Dwell Time.

Notes

  • Minimum 1 element , Maximum 3201 elements

  • MIN/MAX/DEF queries of SCPI are not supported.

  • Frequency unit is not supported in SCPI.

Preset

Maximum RF Frequency (CW)

See Frequency CW

State Saved

Yes

Min

Minimum RF Frequency (CW)

See Frequency CW

Max

Maximum RF Frequency (CW)

See Frequency CW

Resolution

0.00001 Hz

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:FREQuency.

Power

Sets the amplitude for the current List sweep points.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Power

SCPI Command

[:SOURce][:RF<channel>]:LIST:POWer <ampl>,<ampl>

[:SOURce][:RF<channel>]:LIST:POWer?

SCPI Example

:LIST:POW -50,-40

:LIST:POW?

Dependencies

The list size is adjusted so that the same number is used in Frequency, Power, Waveform and Dwell Time. The list number is the maximum row size (list size) in Frequency, Power, Waveform and Dwell Time.

Notes

  • Minimum 1 element, Maximum 3201 elements

  • MIN/MAX/DEF queries of SCPI are not supported.

  • Power unit is not supported in SCPI.

Preset

Minimum RF Power

See Power (Total RMS)

State Saved

Yes

Min

Minimum RF Power

See Power (Total RMS)

Max

Maximum RF Power

See Power (Total RMS)

Resolution

0.01 dBm

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:POWer

Dwell Time

Sets the dwell time for the current List sweep points. Dwell time is the amount of time the sweep is guaranteed to pause after setting the frequency and/or power for the current point, expressed in seconds. It is used when the trigger source of the Point trigger is set to IMMediate.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Dwell Time

SCPI Command

[:SOURce][:RF<channel>]:LIST:DWELl <time>,<time>

[:SOURce][:RF<channel>]:LIST:DWELl?

SCPI Example

:LIST:DWEL 0.001,0.002

:LIST:DWEL?

Dependencies

The list size is adjusted so that the same number is used in Frequency, Power, Waveform and Dwell Time. The list number is the maximum row size (list size) in Frequency, Power, Waveform and Dwell Time.

Notes

  • The value set with this command is not affected by signal generator power–on, preset, or *RST.

  • Minimum 1 element, Maximum 3201 elements

  • MIN/MAX/DEF queries of SCPI are not supported

  • Time unit is not supported in SCPI

Preset

2.00e-3

State Saved

Yes

Min

0.0001

Max

100

Resolution

1e-6 (1 us)

Backwards Compatibility SCPI

N51xxB:

[:SOURce]:LIST:DWELl

Dwell Type

Sets Dwell Type of the list sweep dwell time.

SCPI Command

[:SOURce][:RF<channel>]:LIST:DWELl:TYPE LIST|STEP

[:SOURce][:RF<channel>]:LIST:DWELl:TYPE?

SCPI Example

:LIST:DWEL:TYPE STEP

:LIST:DWEL:TYPE?

Couplings

When set to List, Dwell Type List State is set to ON.

When set to Step, Dwell Type List State is set to OFF.

Preset

LIST

State Saved

Yes

Range

List | Step

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:DWELl:TYPE

Dwell Type List State

Sets the state of the dwell time for the list sweep points between the values defined in the list sweep and the value for the step sweep.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Dwell Time checkbox

SCPI Command

[:SOURce][:RF<channel>]:LIST:DWELl:TYPE:LIST:STATe ON|OFF|1|0

[:SOURce][:RF<channel>]:LIST:DWELl:TYPE:LIST:STATe?

SCPI Example

:LIST:DWEL:TYPE:LIST:STAT ON

:LIST:DWEL:TYPE:LIST:STAT?

Couplings

When set to ON, Dwell Type is set to List.

When set to OFF, Dwell Type is set to Step.

Preset

ON

State Saved

Yes

Current Sweep Point

Remote command only.

Query only. Returns the current sweep point.

SCPI Command

[:SOURce][:RF<channel>]:LIST:CPOint?

SCPI Example

:LIST:CPO?

Notes

When Sweep Type is Step, returns the current sweep point of Step Sweep.

When Sweep Type is List, returns the current sweep point of List Sweep.

State Saved

No

Backwards Compatibility SCPI

N5182B:

[:SOURce]:LIST:CPOint

Waveforms

Sets the waveform values for the current List waveform sequence.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Waveform checkbox selected > Select

SCPI Command

[:SOURce][:RF<channel>]:LIST:WAVeform <string>,<string>

[:SOURce][:RF<channel>]:LIST:WAVeform?

SCPI Example

:LIST:WAV "","WFM1:TEST"

:LIST:WAV?

Dependencies The list size is adjusted so that the same number is used in Frequency, Power, Waveform and Dwell Time. The list number is the maximum row size (list size) in Frequency, Power, Waveform and Dwell Time.

Notes

CW is represented by ""

The number of lists: Min 1, Max 3201 elements

The header information (Sample rate, RMS, Scale, Occupied Bandwidth) is required for the waveform of list sweep. Waveform files which have header information are accepted for the waveform selection.

Files on ARB memory cannot be selected for the list sweep.

Preset

""

State Saved

Yes

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:WAVeform

Frequency Points

Remote command only.

Query only. Returns the current list sweep file for the number of frequency points.

SCPI Command

[:SOURce][:RF<channel>]:LIST:FREQuency:POINts?

SCPI Example

:LIST:FREQ:POIN?

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:FREQuency:POINts?

Power Points

Remote command only.

Query only. Returns the number of power points in the current list sweep file.

SCPI Command

[:SOURce][:RF<channel>]:LIST:POWer:POINts?

SCPI Example

:LIST:POW:POIN?

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:POWer:POINts?

Waveform Points

Remote command only.

Query only. Returns the signal generator for the number of waveform points in the current List sweep file.

SCPI Command

[:SOURce][:RF<channel>]:LIST:WAVeform:POINts?

SCPI Example

:LIST:WAV:POIN?

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:WAVeform:POINts?

Dwell Time Points

Remote command only.

Query only. Returns the signal generator for the number of dwell time points in the current List sweep file.

SCPI Command

[:SOURce][:RF<channel>]:LIST:DWELl:POINts?

SCPI Example

:LIST:DWEL:POIN?

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:DWELl:POINts?

Import List Sweep Table

Imports a List sweep table file.

Supported file formats:

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Import/Export/Preset > Import List Sweep Table

SCPI Command

[:SOURce][:RF<channel>]:LIST:LOAD "<file name>"

SCPI Example

:LIST:LOAD "LIST1"

Notes

Momentary action

State Saved

No

Backward Compatibility SCPI

N51xxB:

:MEMOry:LOAD:LIST

Backwards Compatibility Notes

For N51xxB:

Alias :MEMOry:LOAD:LIST

to

:SOURce:RF1:LIST:LOAD

Export List Sweep Table

Stores the current list sweep table data to a CSV file.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Import/Export/Preset > Export List Sweep Table

SCPI Command

[:SOURce][:RF<channel>]:LIST:STORe "<file name>"

SCPI Example

:LIST:STOR "LIST1"

Notes

Momentary action

State Saved

No

Preset List with Defaults

Replaces the current list sweep data with the default setting consisting of one point at a frequency, amplitude, and dwell time.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Import/Export/Preset > Preset List with Defaults

SCPI Command

[:SOURce][:RF<channel>]:LIST:TYPE:LIST:INITialize:PRESet

SCPI Example

:LIST:TYPE:LIST:INIT:PRES

State Saved

No

Backward Compatibility SCPI

N5182B:

[:SOURce]:LIST:TYPE:LIST:INITialize:PRESet

Preset List with Step Sweep

Replaces the loaded list sweep data with the settings from the current step sweep data points.

GUI Location

RF Output > List / Step Sweep > Edit List Sweep > Import/Export/Preset/ Preset List with Step Sweep

SCPI Command

[:SOURce][:RF<channel>]:LIST:TYPE:LIST:INITialize:FSTep

SCPI Example

:LIST:TYPE:LIST:INIT:FST

Notes The maximum number of List sweep points is 3,201. When copying the Step sweep settings to a List sweep, ensure that the number of points in the Step sweep do not exceed the maximum List sweep points.

State Saved

No

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:TYPE:LIST:INITialize:FSTep

Edit Triggers

Click this button to access the List/Step Sweep Trigger screen. You can use this screen to configure the sweep trigger for List Sweep and Step Sweep.

Sweep Trigger

This section describes the settings of Sweep Trigger.

Trigger Type

Sets the sweep trigger type.

GUI Location

RF Output > List / Step Sweep > Edit Triggers > Sweep Trigger > Trigger Type

SCPI Command

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:TYPE FRUN|SINGle|TRUN

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:TYPE?

SCPI Example

:LIST:SWE:TRIG:TYPE SING

:LIST:SWE:TRIG:TYPE?

Dependencies When you set the Trigger Type to Single or Trigger & Run, the Trigger Source is automatically set to Key if it is currently set to Immediate.

Couplings

When Trigger Source is set to Immediate, Trigger Type is set to FreeRun (if it is currently not set to FreeRun).

Preset

FRUN

Range

  • Free Run (FRUN)

  • Single (SINGle)

  • Trigger & Run (TRUN)

State Saved

Yes

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:SWEep:TRIGger:TYPE

Trigger Source

Per-channel setting

Sets the source for triggering a sweep. Following options are available.

GUI Location

RF Output > List / Step Sweep > Edit Triggers > Sweep Trigger > Trigger Source

SCPI Command

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:SOURce KEY|BUS|EXTernal|IMMediate|GTRigger

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:SOURce?

SCPI Example

:LIST:SWE:TRIG:SOUR EXT

:LIST:SWE:TRIG:SOUR?

Notes

The wait for the BUS, EXTernal, or KEY trigger can be bypassed by sending the Trigger Immediate command.

Couplings

When you set the Trigger Type to Single or Trigger & Run, the Trigger Source is automatically set to Key if it is currently set to Immediate.

Preset

IMM

Range

Key (KEY)

Bus (BUS)

External (EXTernal)

Immediate (IMMediate)

Global Trigger (GTRigger)

State Saved

Yes

Backward Compatibility SCPI

N51xxB:

:TRIGger[:SEQuence]:SOURce

Backward Compatibility Notes

For N51xxB:

Alias :TRIGger[:SEQuence]:SOURce to :SOURce:RF1:LIST:SWEep:TRIGger:SOURce

The selection MANual works as same as KEY.

The selection INTernal is not supported in this release.

External Trigger Source

Sets the external trigger source of Sweep Trigger.

GUI Location

RF Output > List / Step Sweep > Edit Triggers > Sweep Trigger > Trigger Source set to External > Trigger Source

SCPI Command

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:EXTernal:SOURce <integer>

[:SOURce][:RF<channel>]:LIST:SWEep:TRIGger:EXTernal:SOURce?

SCPI Example

:LIST:SWE:TRIG:EXT:SOUR 2

:LIST:SWE:TRIG:EXT:SOUR?

Couplings If the specified connector was being used (not None) as an output, then the Trigger Output Routing of that connector is set to None and a Settings Conflict error message is generated.

Preset

1

State Saved

Yes

Min

1

Max

6 (N5185A / N5186A)

Backward Compatibility SCPI

N51xxB:

:TRIGger:EXTernal:SOURce

Backwards Compatibility Notes 

For N51xxB:

Alias :TRIGger:EXTernal:SOURce to :SOURce:RF1:LIST:SWEep:TRIGger:EXTernal:SOURce

For N5186A,/ N5185A:

  • TRIGger[1] uses 1 (TRIG 1)

  • TRIGger2 uses 2 (Trig 2)

  • PULSe uses 6 (Pulse In)

External Trigger Polarity

Remote command only

Sets the polarity of the external trigger 1 of channel 1.

Refer to the Trigger Input Slope command.

Preset

POS

Range

Positive|Negative

State Saved

Yes

Backwards Compatibility SCPI

N51xxB:

:TRIGger[:SEQuence]:SLOPe

Backwards Compatibility Notes

For N51xxB:

Alias :TRIGger[:SEQuence]:SLOPe to :ROUTe:CONNectors:RF1:TRIG[1]:INPut:SLOPe

Point Trigger

This section describes the settings of Point Trigger for a List or Step sweep event.

Point Trigger Source

Sets the point trigger source for a List or Step sweep event.

GUI Location

RF Output > List / Step Sweep > Edit Triggers > Point Trigger > Trigger Source

SCPI Command

[:SOURce][:RF<channel>]:LIST:TRIGger:SOURce KEY|BUS|EXTernal|IMMediate|GTRigger

[:SOURce][:RF<channel>]:LIST:TRIGger:SOURce?

SCPI Example

:LIST:TRIG:SOUR EXT

:LIST:TRIG:SOUR?

Preset

IMMediate

Range

Key|Bus|External|Immediate|Global Trigger

State Saved

Yes

Backwards Compatibility SCPI

N51xxB:

[:SOURce]:LIST:TRIGger:SOURce

Backwards Compatibility Notes

For N51xxB:

The selection MANual works as same as KEY.

The selection INTernal is not supported on this release.

External Trigger Source

Sets the external trigger source of Point Trigger.

GUI Location

RF Output > List / Step Sweep > Edit Triggers > Point Trigger > Trigger Source set to External > Trigger Source

SCPI Command

[:SOURce][:RF<channel>]:LIST:TRIGger:EXTernal:SOURce <integer>

[:SOURce][:RF<channel>]:LIST:TRIGger:EXTernal:SOURce?

SCPI Example

:LIST:TRIG:EXT:SOUR 2

:LIST:TRIG:EXT:SOUR?

Couplings If the specified connector was being used (not None) as an output, then the Trigger Output Routing of that connector is set to None and a Settings Conflict error message is generated.

Preset

1

State Saved

Yes

Min

1

Max

6 (N5185A / N5186A)

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:TRIGger:EXTernal:SOURce

Backwards Compatibility Notes 

For N51xxB:

For N5186A, N5185A:

  • TRIGger[1] uses 1 (TRIG 1)

  • TRIGger2 uses 2 (Trig 2)

  • PULSe uses 6 (Pulse In)

External Trigger Polarity

Remote command only

Sets the polarity of the external trigger 1 .

Refer to the Trigger Input Slope command.

Preset

POS

Range

Positive|Negative

State Saved

Yes

Backward Compatibility SCPI

N51xxB:

[:SOURce]:LIST:TRIGger:SLOPe

RF Output Block